MCS200HW – Multi-component analyzer system

PROVEN MEASUREMENT TECHNOLOGY FOR FLUE GAS MONITORING

ONE ANALYZER SYSTEM, MANY POSSIBILITIES,

HIGH EFFICIENCY

Lower costs through the use of dry test gases With the MCS200HW, reference point checking and adjustment of HCl and NH3 are possible for the first time exclusively with dry test gases certified according to EN 15267 and EN 14181. Test gas generators or evaporators to create wet test gases are no longer required. This saves time and reduces operating costs. Both for operating entities, e.g. when carrying out the regular QAL3 inspections, and for test institutes, e.g. when carrying out the annual surveillance test (AST).

Reference point check without test gas Thanks to internal adjustment filters, drift checking and adjustment are possible even without a test gas. The reference point position of all infrared-active components can be checked both manually and fully automatically. The reference point check can also be used for quality assurance during operation (QAL3 inspection). Expensive test gases are not necessary and the workload is reduced. This creates security and saves costs – with maximum measuring quality.

Hot/wet extractive measurement technology

The MCS200HW works according to the measurement principle of an infrared single-beam photometer. Both interference and gas filter correlation methods are used. All parts in contact with the sample gas are heated above the dew point to prevent condensate formation in the analyzer system and to avoid damage due to corrosion. Thus, water-soluble gases such as HCl or NH3 can be monitored and are not lost through solubility effects or salt formation. This increases the service life and measurement certainty of the analyzer system.

Product description

The MCS200HW is a multi-component analyzer system for continuous monitoring of up to 10 IR measurement components in flue gases of industrial combustion plants. The MCS200HW is hot/wet extractive: All parts which touch media, from the gas sampling probe to the cell, are heated above the dew point and therefore protected from corrosion.

An integrated oxygen sensor also measures oxygen. As an option, a TOC measurement can be supplemented via an integrated GMS811 FIDORi. Internal reference point monitoring allows for a quick check of the measured values with test gases. The web display and the task assistant integrated in the software makes operation very easy.

At a glance

• Measurement of up to 10 IR components plus O2 and TOC

• Hot/wet extractive measurement technology

• Wear-free gas distribution through ejector pumps

• Reference point monitoring with internal calibration cells

• Certified digital Modbus® interface

• Web server for platform-independent device control

• Use of dry test gases for HCl and NH3

Your benefits

• Reliable measurement results, even for water-soluble gas components

• Only one analyzer necessary for simultaneous monitoring of up to 12 gas components

• Measurement components can be put together flexibly and extended at any time

• Convenient, task-oriented operation

• Remote access without additional software

• High availability due to certified internal third-party monitoring (QAL3) without test gases

• Low service costs thanks to minimal maintenance requirements

• Complete data transmission through only one interface possible